Table 1-1
Koden Scanners

MRT-147
4 kW Peak Power, 22" Radome, 4.0º * 25º beam
Koden MD-3641
4 kW Peak Power, 3' Open Array, 2.4º * 25º beam
Koden MD-3642T, MD-3840T
4 kW Peak Power, 4' Open Array, 1.7º * 25º beam
Koden MD-3642F, MD-3840F

MRT-148
4 kW Peak Power, 18" Radome, 4.7º * 25º beam
Koden MD-3441

 

MRT-152
2 kW Peak Power, 11" Radome, 7º * 25º beam
Koden MD-3420 Mk 2 

RB704A
6 kW Peak Power, 3' Open Array, 2.5º * 22º beam
6 kW Peak Power, 4' Open Array, 1.8º * 22º beam
6 kW Peak Power, 6' Open Array, 1.2º * 22º beam

Koden MDC-3560
Anritsu RA725UA

RB705A
12 kW Peak Power, 3' Open Array, 2.5º * 22º beam
12 kW Peak Power, 4' Open Array, 1.8º * 22º beam
12 kW Peak Power, 6' Open Array, 1.2º * 22º beam
Koden MDC-3510
Anritsu RA726UA

 

RB709A
4 kW Peak Power, 2' Open Array, 3.9º * 25º beam

Koden None remaining on any product list 
Anritsu RA770UA

RB710A
4 kW Peak Power, 3' Open Array, 2.5º * 22º beam
4 kW Peak Power, 4' Open Array, 1.8º * 22º beam
Koden MDC-3510 (3' Antenna only),  MDC-3560 (4' Antenna only)
Anritsu RA771UA

RB714A
2 kW Peak Power, 18" Radome,  5.9º *  30º beam
(There appear to be several possible array versions within the radome enclosure, with minor differences in beamwidth)
Koden MDP-621, MDC-721
Anritsu RA772UA
Northstar R2D
Simrad RA30, CA/CR34, CA/CR40, CA/CR42, CA/CR44, CA/CR50, CA/CR52, CA/CR54
SI-Tex MDP-621, T-721

RB715A
4 kW Peak Power, 24" Radome, 3.9º * 25º beam
Koden MDP-641, MDC-741, MDC-1041, MDC-1541, MDC-1841BB, MDS-51R (RADARpc)
Nobeltec IR2-4D
Northstar RAD4KD/R4KDE-A (6x00-Series)
Simrad RA31, RA41, RA51
SI-Tex MDP-641, MDP-1241, T-741, T-1041, T-1541, RADARpc-4D 

 

RB716A
4 kW Peak Power, 3' Open Array, 2.5º * 22º beam
Koden MDP-640, MDC-740, MDC-1840BB, MDS-52R (RADARpc), MDC-2240
Nobeltec IR2-4.3
Northstar RAD4K35 (6x00-Series)
Simrad CX44/CX54 NavStation, RA32, RA42, RA52
SI-Tex MDP-640, MDP-1240, T-740, T-1040, T-1540, RADARpc-3.5
RB716A
4 kW Peak Power, 4' Open Array, 1.8º * 22º beam
 Koden MDP-640, MDC-740, MDC-1540, MDC-1040, MDC-1840BB, MDS-52R (RADARpc), MDC-2540
Nobeltec IR2-4.4
Northstar RAD4K35 (6x00-Series)
Simrad CX44/54 NavStation, RA32, RA42, RA52
SI-Tex MDP-640, MDP-1240, T-1040, T-1540, RADARpc-4.5

RB717A
6 kW Peak Power, 4' Open Array, 1.8º * 22º beam
6 kW Peak Power, 6' Open Array, 1.2º * 22º beam

Koden MDC-1060, MDC-1560, MDC-1860,  MDC-1860BB, MDS-61R (RADARpc), MDC-3560 (MDC-2260, 4' Antenna only), (MD-2560, 6' Antenna only)
Anritsu RA725UA
Nobeltec IR2-6.4
Northstar RAD6KE45 (6x00-Series) (4' Antenna only), RAD6KE65 (6x00-Series) (6' Antenna only)
Simrad CX44/54 NavStation, RA43, RA53, RA73, RA725UA
SI-Tex MDP-1260, T-1560, RADARpc-6.4

RB718A
12 kW Peak Power, 4' Open Array, 1.8º * 22º beam
Koden MDC-1010, MDC-1510, MDC-1710, MDC-1810, MDC-1810BB, MDC-1810P, MDC-1910, MDS-62R (RADARpc), MDC-3510, MDC-2210
Nobeltec IR2-12.4 (4' Antenna only), IR2-12.6 (6' Antenna only)
Northstar RAD12KE65 (6x00-Series) (6' Antenna only)
Simrad CX44/54 NavStation, RA44, RA54, RA74, RA725UA (4' Antenna only),  RA726UA (6' Antenna only)
SI-Tex MDP-1210, RADARpc-12.4 (4' Antenna only), RADARpc-12.6 (6' Antenna only)
RB719A
25 kW Peak Power, 4' Open Array, 1.8º * 22º beam
25 kW Peak Power, 6' Open Array, 1.2º * 22º beam
25 kW Peak Power, 9' Open Array, 0.8º * 25º beam
(The RB719A scanner is also used by Simrad in its 6-kW model RA83P/RA93P; and 12-kW model RA84P/RA94P)
Koden MDC-1520, MDC-1720, MDC-1820, MDC-1820BB, MDC-1820P, MDC-1920MDC-2520 (not 4' Antenna)MDS-63R (RADARpc), MDC-3510
Nobeltec IR2-25.4 (4' Antenna only), IR2-25.6 (6' Antenna only), IR2-25.9 (9' Antenna only)
Northstar RAD25KE65 (6x00-Series) (6' Antenna only), 
Simrad RA55, RA85, RA85P, RA95, RA95P
SI-Tex MDP-1210, RADARpc-25.4 (4' Antenna only), RADARpc-25.6 (6' Antenna only), RADARpc-25.9 (postulated, 9' Antenna)